Flow Meters

SHOWING 1–10 OF 11 RESULTS

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 100 mm

    000219
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 100 mm – 4″
    • Over load Flow: 250 m³/hr
    • Permanent Flow: 180 m³/hr
    • Transitional Flow: 2 m³/hr
    • Minimum Flow (Horizontal): 0.60 m³/hr
    • Minimum Flow (Vertical): 1.2 m³/hr
    • Head Loss at Maximum Flow: 0.43 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar
     45,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 125 mm

    000220
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 125 mm – 5″
    • Over load Flow: 250 m³/hr
    • Permanent Flow: 180 m³/hr
    • Transitional Flow: 2 m³/hr
    • Minimum Flow (Horizontal): 0.60 m³/hr
    • Minimum Flow (Vertical): 1.2 m³/hr
    • Head Loss at Maximum Flow: 0.58 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar

    For price and more details, please Contact Us

     70,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 150 mm

    000221
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 150 mm – 6″
    • Over load Flow: 600 m³/hr
    • Permanent Flow: 150 m³/hr
    • Transitional Flow: 4 m³/hr
    • Minimum Flow (Horizontal): 1.80m³/hr
    • Minimum Flow (Vertical): 4.5 m³/hr
    • Head Loss at Maximum Flow: 0.33 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar

    For price and more details, please Contact Us

     85,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 200 mm

    000222
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 200 mm – 8″
    • Over load Flow: 1,000 m³/hr
    • Permanent Flow: 700 m³/hr
    • Transitional Flow: 6 m³/hr
    • Minimum Flow (Horizontal): 4.0 m³/hr
    • Minimum Flow (Vertical): 7.5 m³/hr
    • Head Loss at Maximum Flow: 0.32 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar

    For price and more details, please Contact Us

     110,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 250 mm

    000223
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 250 mm – 10″
    • Over load Flow: 1,600 m³/hr
    • Permanent Flow: 1,000 m³/hr
    • Transitional Flow: 11 m³/hr
    • Minimum Flow (Horizontal): 6.0 m³/hr
    • Minimum Flow (Vertical): 12.0 m³/hr
    • Head Loss at Maximum Flow: 0.37 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar

    For price and more details, please Contact Us

     240,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 300 mm

    000224
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 300 mm – 12″
    • Over load Flow: 2,000 m³/hr
    • Permanent Flow: 1,500 m³/hr
    • Transitional Flow: 15 m³/hr
    • Minimum Flow (Horizontal): 12.0 m³/hr
    • Minimum Flow (Vertical): 18.0 m³/hr
    • Head Loss at Maximum Flow: 0.58 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar

    For price and more details, please Contact Us

     295,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 40mm

    000215
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 40mm – 1½”
    • Over load Flow: 90 m³/hr
    • Permanent Flow: 50 m³/hr
    • Transitional Flow: 1 m³/hr
    • Minimum Flow (Horizontal): 0.35 m³/hr
    • Minimum Flow (Vertical):0.45 m³/hr
    • Head Loss at Maximum Flow: 0.84 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar
     36,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 50mm

    000216
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 50 mm – 2″
    • Over load Flow: 90 m³/hr
    • Permanent Flow: 50 m³/hr
    • Transitional Flow: 1 m³/hr
    • Minimum Flow (Horizontal): 0.35 m³/hr
    • Minimum Flow (Vertical):0.45 m³/hr
    • Head Loss at Maximum Flow: 0.49 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar
     37,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 65mm

    000217
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 65 mm – 2½”
    • Over load Flow: 120 m³/hr
    • Permanent Flow: 65 m³/hr
    • Transitional Flow: 1.5 m³/hr
    • Minimum Flow (Horizontal): 0.40 m³/hr
    • Minimum Flow (Vertical):0.75 m³/hr
    • Head Loss at Maximum Flow: 0.69 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar
     40,000.00

  • Elster H4000 Woltmann-Cold Water Meter Flanged Type 80 mm

    000218
    The H4000 is a Woltmann-type meter designed for measuring bu
    Quick Overview
    • Meter Size: 80 mm – 3″
    • Over load Flow: 200 m³/hr
    • Permanent Flow: 120 m³/hr
    • Transitional Flow: 2 m³/hr
    • Minimum Flow (Horizontal): 0.50 m³/hr
    • Minimum Flow (Vertical): 1.2 m³/hr
    • Head Loss at Maximum Flow: 0.27 bar
    • Maximum Water Temperature: 50°C
    • Maximum Working Pressure: 16 bar
     42,000.00